YASKAWA AC DRIVE (VFD) PRODUCT CATALOG – ALL SERIES ON SALE (2026)
YASKAWA AC Drive (VFD) Product Catalog — All Series On Sale (2026)
Table of Contents
This catalog lists the Yaskawa AC drive (variable frequency drive / inverter) series currently sold worldwide, compiled in August 2026 from official Yaskawa sources (yaskawa.com, yaskawa.eu.com, yaskawa.com.cn, yaskawa-global.com). Power ranges show standard catalog ratings (Normal Duty / Heavy Duty where applicable); exact ratings, model codes and certifications vary by region. Always confirm the availability and exact part number with your local Yaskawa authorized distributor before ordering

1. General Purpose Drives
| No. | Series | Category | Positioning | Voltage Class | Power Range | Max. Output Freq. | Motor Types | Overload (HD) | Enclosure | Key Applications | Typical Model Prefix | Status |
| 1 | GA500 | General Purpose | AC microdrive for industrial applications; compact, high power density | 200 V 3-ph; 400 V 3-ph | 0.18-15 kW (200V) / 0.37-30 kW (400V) | 590 Hz | Induction, PM, SynRM | 150% / 60 s | IP20 | Packaging, textile, conveyors, small machines, fans & pumps | CIMR-GA5A / GA5C | Current (successor to V1000) |
| 2 | GA700 | General Purpose | High-performance general-purpose drive; EZ vector, up to 630 kW | 200 V 3-ph; 400 V 3-ph | 0.4-110 kW (200V) / 0.4-630 kW (400V) | 590 Hz | Induction, PM, SynRM | 150% / 60 s | IP20 (NEMA 1 kit) | Machine tools, injection molding, cranes, winding, fans & pumps, elevators (traction) | CIMR-GA7A / GA7C | Current |
| 3 | GA800 | General Purpose | General-purpose drive for standard & heavy duty; NA/global flagship | 240 V; 480 V; 600 V (3-ph) | 1-150 HP (240V) / 1-1000 HP (480V) / 125-500 HP (600V) | 590 Hz | Induction, PM, SynRM | 150% / 60 s (HD); 110% / 60 s (ND) | IP20/Type 1, Type 12, Type 3R | General industry, fans & pumps, test dynamometers, conveyors | GA80U-xxxx | Current (successor to A1000 in NA) |
| 4 | A1000 | General Purpose | High-performance vector-control drive (previous flagship) | 200 V; 400 V (3-ph) | 0.4-110 kW (200V) / 0.4-630 kW (400V) | 590 Hz | Induction, PM | 150% / 60 s | IP20 | Industrial machinery, fans, pumps, conveyors, hoists | CIMR-AB / CIMR-AC | Legacy; still listed in many markets |
| 5 | V1000 | General Purpose | Compact vector-control microdrive | 200 V; 400 V (3-ph) | 0.1-15 kW (200V) / 0.2-18.5 kW (400V) | 590 Hz | Induction, PM | 150% / 60 s | IP20 | Small machines, fans, pumps, elevators (some markets) | CIMR-V2A / V4A | Legacy; being phased out by GA500 |
| 6 | J1000 | General Purpose | Compact V/f microdrive; cost-effective value line | 200 V 1-ph; 200/400 V 3-ph | 0.1-2.2 kW (1-ph) / 0.1-15 kW (3-ph) | 400 Hz | Induction | 150% / 60 s | IP20 | Small fans, pumps, conveyors, doors, curtains | CIMR-JC… | Current (value line) |
| 7 | U1000 | General Purpose | Industrial drive with encoder feedback (closed loop) | 200 V; 400 V (3-ph) | 0.4-110 kW (200V) / 0.4-630 kW (400V) | 590 Hz | Induction, PM | 150% / 60 s | IP20 | Machine tools, printing, textile, winding | CIMR-U2A / U4A | Legacy; replaced by GA800 in NA |
| 8 | H1000 | Heavy Duty | Heavy-duty industrial drive for tough environments | 240 V; 480 V (3-ph) | 3-200 HP (240V) / 3-1000 HP (480V) | 590 Hz | Induction | 150% / 60 s | IP20 | Mining, metals, cement, heavy industry | CIMR-H2A / H4A | Legacy (NA) |
| 9 | E1000 | Crane / Industrial | Industrial drive optimized for hoists & cranes | 240 V; 480 V (3-ph) | 3-150 HP (240V) / 3-700 HP (480V) | 590 Hz | Induction | 150% / 60 s | IP20 | Hoists, cranes, winches, elevators (some markets) | CIMR-E2A / E4A | Legacy (NA) |
2. Regenerative Drives
| No. | Series | Category | Positioning | Voltage Class | Power Range | Max. Output Freq. | Motor Types | Overload (HD) | Enclosure | Key Applications | Typical Model Prefix | Status |
| 1 | R1000 | Regenerative | Regenerative drive – returns energy to the line | 200 V; 400 V (3-ph) | 5.5-110 kW (200V) / 5.5-630 kW (400V) | 590 Hz | Induction, PM | 150% / 60 s | IP20 | Test stands, winders, elevators (regenerative), cranes | CIMR-R2A / R4A | Current (global) |
| 2 | D1000 | Regenerative | Regenerative drive (NA market) | 240 V; 480 V (3-ph) | 10-200 HP (240V) / 10-1000 HP (480V) | 590 Hz | Induction | 150% / 60 s | IP20 | NA equivalent of R1000; regenerative applications | CIMR-D2A / D4A | Legacy (NA) |
3. Fan & Pump / HVAC Drives
| No. | Series | Category | Positioning | Voltage Class | Power Range | Max. Output Freq. | Motor Types | Overload (HD) | Enclosure | Key Applications | Typical Model Prefix | Status |
| 1 | FP605 | Fan & Pump | Dedicated fan & pump drive; energy-saving pump control | 240 V; 480 V (3-ph) | 3-150 HP (240V) / 3-600 HP (480V) | 400 Hz | Induction, PM, SynRM | 110% / 60 s | IP20/Type 1, IP55/Type 12, Type 3R | Industrial fans, pumps, cooling towers, irrigation | FP605 / FP60… | Current (successor to P1000) |
| 2 | HV600 | HVAC | HVAC / building-automation drive with embedded BAS protocols | 208-240 V; 480 V (3-ph) | 3-100 HP (240V) / 3-250 HP (480V) standalone; bypass/config 0.5-100 / 0.75-250 HP | 400 Hz | Induction, PM, SynRM | 110% / 60 s | IP20/Type 1, IP55/Type 12, Type 3R | HVAC fans, pumps, cooling towers, multiplex pumping | HV600 / H6B… | Current (successor to Z1000) |
| 3 | Z1000 | HVAC | HVAC drive (previous generation) | 240 V; 480 V (3-ph) | 3-300 HP (240V) / 3-1000 HP (480V) | 400 Hz | Induction | 110% / 60 s | IP20/Type 1 | HVAC fans, pumps, building automation | CIMR-Z2A / Z4A | Legacy (NA); replaced by HV600 |
| 4 | P1000 | HVAC | Fan & pump drive (previous generation) | 240 V; 480 V (3-ph) | 3-300 HP (240V) / 3-1000 HP (480V) | 400 Hz | Induction | 110% / 60 s | IP20/Type 1 | Fans, pumps, HVAC | CIMR-P2A / P4A | Legacy (NA); replaced by FP605 |
4. Elevator / Lift Drives
| No. | Series | Category | Positioning | Voltage Class | Power Range | Max. Output Freq. | Motor Types | Overload (HD) | Enclosure | Key Applications | Typical Model Prefix | Status |
| 1 | LA700 | Elevator | New-generation lift drive (replaces L1000A); smooth ride, SIL3 safety | 200 V 3-ph; 400 V 3-ph | 3.7-110 kW (200V) / 3.7-160 kW (400V) | 200 Hz | Induction, PM (geared & gearless) | 175% / 30 s (3M starts) | IP20 | Elevators: geared & gearless, MRL, high-speed (up to 4 m/s), modernization | CIPR-LA70C2 / LA70C4 | Current (Europe 2023 / China 2024 / Japan 2024) |
| 2 | LA500 | Elevator | Lift microdrive for geared elevators (open loop) | 200 V 3-ph; 400 V 3-ph | 4-18.5 kW (200V) / 4-22 kW (400V) | 200 Hz | Induction (geared) | 165% / 30 s | IP20 | Geared lift new installs & modernization (up to 1.6 m/s) | LA500 | Current |
| 3 | L1000A | Elevator | Lift drive (previous generation); IM & PM control | 200 V; 400 V (3-ph) | 3.7-110 kW (200V) / 3.7-160 kW (400V) | 200 Hz | Induction, PM | 150% / 60 s (HD) | IP20 | Elevators: new installs, MRL, retrofit/modernization | CIMR-LC2A / LC4F | Legacy; still sold for modernization |
| 4 | ES700 | Elevator | Elevator dedicated drive (China); comfort, safety & energy saving | 200 V 3-ph; 400 V 3-ph | 3.7-110 kW (200V) / 3.7-160 kW (400V) | 400 Hz | Induction, PM | 150% / 60 s (50% ED lift rating) | IP20 | Passenger & freight elevators, escalator drive, residential & commercial | CIPR-ES70C2 / ES70C4 | Current (China market, launched 2024) |
5. Crane Drives
| No. | Series | Category | Positioning | Voltage Class | Power Range | Max. Output Freq. | Motor Types | Overload (HD) | Enclosure | Key Applications | Typical Model Prefix | Status |
| 1 | CR700 | Crane | Crane-specialized drive (global); anti-sway, tandem, brake sequence | 200 V; 400 V (3-ph) | 0.4-110 kW (200V) / 0.4-315 kW (400V) | 590 Hz | Induction | 150% / 60 s | IP20 | Hoists, trolleys, overhead cranes, gantry cranes | CIPR-CR70C4… | Current |
| 2 | CH700 | Crane | Crane-specialized drive (China/Asia); brake sequence control | 200 V; 400 V (3-ph) | 0.4-110 kW (200V) / 0.4-315 kW (400V) | 590 Hz | Induction, PM | 150% / 60 s | IP20 | Cranes, hoists, winches, lifting machinery | CIPR-CH70B4… | Current (China/Asia) |
6. Medium-Voltage Drives
| No. | Series | Category | Positioning | Voltage Class | Power Range | Max. Output Freq. | Motor Types | Overload (HD) | Enclosure | Key Applications | Typical Model Prefix | Status |
| 1 | MV1000 | Medium Voltage | Medium-voltage drive (FSDrive-MV1000 family) | 3.3 kV; 6.0 kV; 6.6 kV | Project-based (typical 200-3000 kW) | – | Induction | – | IP21/IP54 | Large pumps, fans, compressors, conveyors, marine | CIMR-MV… | Current (project-based) |
Notes
- Elevator (lift) applications — most relevant for the elevator parts trade:
- LA700: new-generation lift drive, recommended for new installations (replaces L1000A);
- ES700: elevator dedicated drive for the China market;
- L1000A: previous generation, still widely used for modernization and spare parts;
- LA500: micro drive for geared lifts (open loop).
- General-purpose drives (GA500 / GA700 / GA800) are also frequently used in elevator traction and machine-room applications.
- ‘Legacy’ series (A1000, V1000, U1000, H1000, E1000, D1000, Z1000, P1000, L1000A) are no longer the default choice for new designs in some regions, but remain on sale for replacement, spare parts and modernization projects.
- YASKAWA is a registered trademark of Yaskawa Electric Corporation. This document is an independent compilation for reference; specifications are subject to change without notice.
About the Yaskawa AC drive and elevator spare parts
To order yaskawa elevator and escalator parts, send the exact model or reference code printed on the original component to [email protected]. Please quote the complete code including any suffix so that our team can confirm the correct variant, current stock and lead time before you commit.
Yaskawa AC drive series we supply
Elevator and escalator control systems are built around a relatively small number of serviceable assemblies: the drive and motion controller, the main control or mother board, the power stage, the encoder feedback interface, and the door or brake control module. We stock yaskawa parts that fail most often in daily service, including drive boards, mother boards, encoders, door operators and brake modules. Each carries its own set of reference numbers depending on the original equipment manufacturer and the revision of the installation.
All yaskawa parts we supply are inspected before dispatch. Boards are checked for physical damage, capacitor condition and connector integrity, and are packed to survive international transit. Where a superseded revision is the only one available, we state that clearly and explain the substitution so that the installing engineer can make an informed decision.
Yaskawa AC drive buying guidance and compatibility
Before ordering yaskawa elevator and escalator parts, confirm three things. First, the exact part number and revision from the failed unit. Second, the equipment model and controller family it was installed in, since the same board can be used across several product lines. Third, whether the installation is a traction lift or an escalator, as the duty cycle and current rating differ between the two.
If you are unsure which revision of the yaskawa you need, send a photograph of the nameplate and the existing board alongside the fault description. That is usually enough for our team to identify the correct replacement without a site visit, and it avoids the cost and delay of returning an incompatible part. We are also happy to advise on the other serviceable assemblies in the same controller, so that a planned shutdown can cover several wear items at once.
Related Yaskawa AC drive parts and further reading
If you are servicing a complete controller, these related pages may help you plan the work:
- Elevator parts catalogue — browse the full range of spare parts we supply.
- Elevator control boards — mother boards, drive boards and power boards.
- Contact our sales team — request a quotation or compatibility check.
Yaskawa AC drive reference sources
The compatibility information on this page was cross-checked against the following authoritative references. Always confirm the exact part number against your own equipment nameplate.
- ISO 8100-1 lift safety standard — international requirements covering lift components and control systems.
- International Electrotechnical Commission (IEC) — the standards body for electrical equipment used in lift and escalator installations.
- Otis — original equipment manufacturer service and parts reference.