Otis OVF03B-402 inverter
Table of Contents
Otis OVF03B-402 inverter
Otis LRU-402 inverter
Model Number: KAA21305ABZ4

XiziOtis ACD4-MR inverter
Model Number: KAA21305ABZ6

Otis
A United Technologies Company
Inside Board is KCA26800ABS8,KCA26800ABS4 and KEA26800ABS8,KEA26800ABS4
We can also provide Otis OVF03B-402 inverter

Ordering the otis ovf03b-402 inverter
To order the otis ovf03b-402 inverter, send us a photograph of the existing unit and its nameplate at [email protected]. Please quote the complete code including any revision suffix so that our team can confirm the correct variant, current stock and lead time before you commit.
About the otis ovf03b-402 inverter
Elevator and escalator installations are built around a relatively small number of serviceable assemblies, but they fail at very different rates. The otis ovf03b-402 inverter sits in the control board / PCB group, and it is replaced on a different service interval from the assemblies around it. In practice the failures we see on otis ovf03b-402 inverter come down to electrolytic capacitor ageing, cracked solder joints around the power stage, corroded edge connectors, and blown output transistors after a supply fault.
Every otis ovf03b-402 inverter we supply is inspected before dispatch. Each unit is checked for physical damage, correct marking and the specific wear or degradation patterns that matter for this class of component, then packed to survive international transit. Where a superseded revision is the only one available, we say so plainly and explain the substitution, so the installing engineer can make an informed decision rather than discovering the difference on site.
Buying guidance and compatibility notes
Before ordering the otis ovf03b-402 inverter, confirm three things. First, the controller catalogue number and the board revision letter, plus the fault code stored in the controller memory. Second, the same board is frequently fitted across several controller families, so the equipment model alone is not enough to identify the right revision. Third, whether the installation is a traction lift or an escalator, since duty cycle and loading differ between the two.
On fitting, one point is worth repeating: discharge the DC bus before removing a power board, and photograph the connector layout before you unplug anything. Almost every repeat failure we see on otis ovf03b-402 inverter traces back to a related component that was left in place, or to an adjustment that was assumed rather than measured.
Control electronics dominate the failure statistics on any lift older than about twelve years. The boards themselves are usually sound; what fails is the surrounding hardware — capacitors that have dried out, connectors that have oxidised in a humid machine room, and solder joints that have cracked under years of thermal cycling.
When a customer reports a drive that trips on acceleration but runs normally at low speed, our first question is about aging electrolytic capacitors that have lost capacitance rather than failed outright rather than about the electronics.
Anti-static handling is not a formality. A board that works perfectly on the bench can be destroyed by a discharge too small for a technician to feel, which is why stock travels in shielded bags and is unpacked only at the point of fitting.
If you are unsure which variant of the otis ovf03b-402 inverter you need, send a photograph of the nameplate and the existing component alongside a description of the fault. That is usually enough for our team to identify the correct replacement without a site visit, and it avoids the cost and delay of returning an incompatible part. We are also happy to advise on the other serviceable items in the same control board / PCB group, so a planned shutdown can cover several wear items at once.
Related parts and further reading
Because otis ovf03b-402 inverter is only one item in the control board / PCB group, these related pages may help you plan the work:
- Elevator spare parts
- Door Operator Controller
- Elevator Display
- Elevator Encoder
- Elevator Service Tool
Reference sources
The compatibility information on this page was cross-checked against the following authoritative references. Always confirm the exact reference against your own equipment nameplate.

Sindhu
Hi – I am looking for KCA26800ABS8 ACD4 drive, for Volt/Frquency-415v/5 HZ
Capacity 1000Kgs Speed 1m/s weight 68kg
Please let me know if you can provide it, cost and timeline.
[email protected]
KCA26800ABS8 board is USD XXX/pc
This is the price of the board
And inverter price need the name plate to check.
priska
Hi, do you have Drive OVF03B-402 for Otis elevator C3NE3674?
[email protected]
OVF03B-402 inverter is USD 1300/pc-USD 1800/pc, delivery time is within 24hours
And 100% new with otis original package.
OVF03B-402
Please tell us the model number.
The software versions of different models are different. If they are not correct, you can’t replace them on your side.
KBA21310ABF2/KBA21310ABF1/KBA21310ABF3
Weights
15KG
65cm*40cm*30cm
dipl.eng.Emmanuele
Dear Sirs .
Please send your best offer for OTIS INVERTER
1] OVF 10 , DUTY 9 KW same as my attachment file .
2] OVF 20 , DUTY 15 KW for traction machine 160 Vat .
Waiting your comments .
Regards
Dipl.eng.Emmanuele
Mba-iukb/mae-usa.u
[email protected]
Dear Sir,
How are you.
Thanks for your inquiry.
ovf10 9KW otis inverter has been stop produce for many years, there are only have second-hand ones in the market
Which is USD 715/pc, delivery time is 1-2 days and six month warranty.
ovf20 15KW otis inverter has been stop produce for many years, there are only have second-hand ones in the market
Which is USD 820/pc, delivery time is 1-2 days and six month warranty.
Chinese New year is coming, it is the biggest holidays in china
and we will come back to work Feb24.
harendra
1pcb
[email protected]
Hello Dear harendra,
How are you.
Otis OVF03B-402 inverter
OVF03B-402 inverter is USD 1300/pc, delivery time is within 24hours
And 100% new with otis original package.