Kone Hall indicator KM713550G02
Table of Contents
Kone Hall indicator KM713550G02
Ordering the kone hall indicator
To order the kone hall indicator, send the exact model or reference code printed on the original part to [email protected]. Please quote the full code including any suffix so that our team can confirm the correct variant, current stock and lead time before you commit.
About the kone hall indicator
Elevator and escalator installations are built around a relatively small number of serviceable assemblies, but they fail at very different rates. The kone hall indicator sits in the control board / PCB group, and it is replaced on a different service interval from the assemblies around it. In practice the failures we see on kone hall indicator come down to electrolytic capacitor ageing, cracked solder joints around the power stage, corroded edge connectors, and blown output transistors after a supply fault.
Every kone hall indicator we supply is inspected before dispatch. Each unit is checked for physical damage, correct marking and the specific wear or degradation patterns that matter for this class of component, then packed to survive international transit. Where a superseded revision is the only one available, we say so plainly and explain the substitution, so the installing engineer can make an informed decision rather than discovering the difference on site.
Buying guidance and compatibility notes
Before ordering the kone hall indicator, confirm three things. First, the controller catalogue number and the board revision letter, plus the fault code stored in the controller memory. Second, the same board is frequently fitted across several controller families, so the equipment model alone is not enough to identify the right revision. Third, whether the installation is a traction lift or an escalator, since duty cycle and loading differ between the two.
On fitting, one point is worth repeating: discharge the DC bus before removing a power board, and photograph the connector layout before you unplug anything. Almost every repeat failure we see on kone hall indicator traces back to a related component that was left in place, or to an adjustment that was assumed rather than measured.
The practical difficulty with legacy boards is that the original manufacturer may have revised the design three or four times without changing the order code. A board that looks identical to the one you removed can be electrically different, and fitting the wrong revision is a common cause of repeat faults.
If the installation is showing a fault code that clears on reset and returns days later, the identification route is straightforward: a photograph of the board, front and back, is usually faster than any description and avoids a return for the wrong revision.
If you are unsure which variant of the kone hall indicator you need, send a photograph of the nameplate and the existing component alongside a description of the fault. That is usually enough for our team to identify the correct replacement without a site visit, and it avoids the cost and delay of returning an incompatible part. We are also happy to advise on the other serviceable items in the same control board / PCB group, so a planned shutdown can cover several wear items at once.
Related parts and further reading
Because kone hall indicator is only one item in the control board / PCB group, these related pages may help you plan the work:
- Elevator spare parts
- Door Operator Controller
- Elevator Display
- Elevator Encoder
- Elevator Service Tool
Reference sources
The compatibility information on this page was cross-checked against the following authoritative references. Always confirm the exact reference against your own equipment nameplate.

Carlos Abate
I have an old KM713540G01, so can I use this new one?
So I need a KM713500G01 too.
How much do they cost (one of each) and placed in Venezuela?
Best regards
[email protected]
We only have this KM713550G01 and KM713550G02 Elevadores indicator.
And sending to your city will cost USD60 and need 4-7 days