KM713380G02 TRANSFORMER,CURRENT 400V
Table of Contents
KM713380G02 TRANSFORMER,CURRENT 400V

KM50011240G03 CONTROL CURRENT TRANSFORMER 1000VA
Gross weight: 6,69
KM50011240G02 TRANSFORMER,CURRENT CONTROL
Gross weight: 8,73
KM713380G01 TRANSFORMER,CURRENT 400V 500VA LCE
Gross weight: 4,12
POWER RATING
500VA
PRIMARY VOLTAGE
400V
SECONDARY VOLTAGE
230/20/20V
NUMBER OF OUTPUT
3
DIAMETER
130MM
KM713380G02 TRANSFORMER,CURRENT 400V 630VA 50/60HZ
Gross weight: 5,94
POWER RATING
630VA
PRIMARY VOLTAGE
400V
SECONDARY VOLTAGE
230/20/20V
NUMBER OF OUTPUT
3
DIAMETER
140MM
KM713380G01/KM713380G02 TRANSFORMER,CURRENT 400V 500VA LCE
Elevator PCB cabine box Transformer 630VA 50/60 HZ Control Cabinet Ring KM713380G02
Elevator Transformer KM713380G02 for Kone Elevator Parts
Kone Elevator Transformer KM713380G02 Machine-Room-Less Circle Transformer
KM50011240G03 CONTROL CURRENT TRANSFORMER 1000VA
Ordering the km713380g02 transformer
To order the km713380g02 transformer, send us a photograph of the existing unit and its nameplate at [email protected]. Please quote the complete code including any revision suffix so that our team can confirm the correct variant, current stock and lead time before you commit.
About the km713380g02 transformer
Elevator and escalator installations are built around a relatively small number of serviceable assemblies, but they fail at very different rates. The km713380g02 transformer sits in the control board / PCB group, and it is replaced on a different service interval from the assemblies around it. In practice the failures we see on km713380g02 transformer come down to electrolytic capacitor ageing, cracked solder joints around the power stage, corroded edge connectors, and blown output transistors after a supply fault.
Every km713380g02 transformer we supply is inspected before dispatch. Each unit is checked for physical damage, correct marking and the specific wear or degradation patterns that matter for this class of component, then packed to survive international transit. Where a superseded revision is the only one available, we say so plainly and explain the substitution, so the installing engineer can make an informed decision rather than discovering the difference on site.
Buying guidance and compatibility notes
Before ordering the km713380g02 transformer, confirm three things. First, the controller catalogue number and the board revision letter, plus the fault code stored in the controller memory. Second, the same board is frequently fitted across several controller families, so the equipment model alone is not enough to identify the right revision. Third, whether the installation is a traction lift or an escalator, since duty cycle and loading differ between the two.
On fitting, one point is worth repeating: discharge the DC bus before removing a power board, and photograph the connector layout before you unplug anything. Almost every repeat failure we see on km713380g02 transformer traces back to a related component that was left in place, or to an adjustment that was assumed rather than measured.
When a drive or mother board is replaced, it is worth checking the DC bus capacitors and the cooling path at the same time. A board that failed from overheating will fail again if the fan or heatsink is left as it was.
The underlying cause is usually hairline cracks in solder joints around the power devices after years of thermal cycling, which is why a photograph of the board, front and back, is usually faster than any description and avoids a return for the wrong revision.
The power stage is where most board failures originate, and it is usually a symptom rather than a cause. Blown output devices normally follow a motor, cable or supply fault, so replacing the board without finding the underlying problem is a reliable way to destroy the replacement as well.
If you are unsure which variant of the km713380g02 transformer you need, send a photograph of the nameplate and the existing component alongside a description of the fault. That is usually enough for our team to identify the correct replacement without a site visit, and it avoids the cost and delay of returning an incompatible part. We are also happy to advise on the other serviceable items in the same control board / PCB group, so a planned shutdown can cover several wear items at once.
Related parts and further reading
Because km713380g02 transformer is only one item in the control board / PCB group, these related pages may help you plan the work:
- Elevator spare parts
- Door Operator Controller
- Elevator Display
- Elevator Encoder
- Elevator Service Tool
Reference sources
The compatibility information on this page was cross-checked against the following authoritative references. Always confirm the exact reference against your own equipment nameplate.
